Association of Postconsumer Plastic Recyclers - Design Guidelines, HDPE, PET, PVC Polypropylene Contact APR | Guidelines
APR Home, press releases, opinions, notes to visitors, archives
guidelines, tools, pet, pvc, polypropylene, hdpe
APR members, affiliates, etc.
About APR, Champions for Change, Awards
Contact the Association of Post Consuerm Plastic Recyclers
 
 

testing procedures: bleeding labels
Home > About APR > Testing Procedures > Bleeding Labels

WITHIN THIS SECTION
About APR
Champions for Change
- Critical Issues
Awards

Testing Procedures
- Bleeding Labels
- Barriers
- Dissolution
- Flake

SEE ALSO
Design Guidelines
Guidelines At-A-Glance

 
 

Protocol for Producing PET Flake for Evaluation and Evaluating for Discoloration from “Bleeding Labels”
The following protocol is designed to provide a generic wash process for evaluation of the effects of “bleeding labels” on recycled PET material. A “bleeding label” is one with water dispersible or soluble inks that result in discolored wash water and stained PET flake

This protocol does not purport to address all of the safety issues, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

 Equipment/Supplies List  

  • Label for evaluation, 0.3 grams per test.
  • Clean, PET flakes about 1 cm (3/8 inch) nominal (100 grams/test plus 100 grams for control)
  • Beaker 800 ml. The beaker ID should be about 9 cm (3.5 inches) and have a slurry height to diameter ratio of 0.8
  • 500 to 800 ml beaker, for mixing solution
  • Hot plate capable of heating to 90 0C
  • 125 mm watch glass to cover beaker when heating
  • Scale or balance capable of measuring 500 (+\- 0.5)grams
  • Overhead stirrer capable of 600 rpm
  • Stirring impeller - pitched, and 4 cm (1.75 inch) diameter.
  • Colorimeter/spectrophotometer
  • Thermometer
  • Strainer - non-aluminum, fine mesh
  • Distilled or deionized Water
  • Graduated cylinder, 500 ml
  • Triton X- 100 nonionic surfactant (available from Union Carbide at 1-800-969-2707)
  • Caustic (granular NaOH)

Be sure to read all material safety data sheets.

Developed by Rutgers, The State University of New Jersey, Center for Plastics Recycling Research, - Busch Campus, Piscataway, NJ 08855, for NAPCOR, National Association for PET Container Resources

 PET Sample Wash Procedure
Be sure to use appropriate laboratory safety procedures / Gloves, safety glasses, etc.

  • Cut up 0.3 grams of label into 0.7 cm (1/4 inch) squares.
  • Prepare “wash” solution in the mixing beaker consisting of 400 ml water (for a slurry ratio of 4:1), 0.3% by weight (1.2 grams of Triton X-l00) and 1.0% by weight (4 grams) caustic (NaOH).

    Note: Triton X-100 must be dissolved in cold water prior to the addition of caustic!
  • Add “wash solution” to 800 ml beaker. Heat solution on hot plate to 85C (185 0F) while covered with watch glass cover to minimize evaporation.
  • Add the 0.3 gramsof label and 100 grams of clean, clear PET flake to the solution
  • . Insert overhead stirrer so that the impeller is 1/2 inch above the bottom of the beaker.
  • Turn on overhead stirrer and adjust to 540 rpm.
  • Continue agitation for 15 minutes and maintain solution at 85C (185F)
  • Turn off and remove overhead stirrer. Remove beaker from heat and immediately strain solution, labels, and flake. Save solution for visual observation
  • Immediately rinse the remaining labels and PET flake with distilled or deionized water, approximately with 200 ml of water. Separate and dry the PET flake from the slurry.
  • 10. To prepare the control PET flake for comparison, follow above procedure while omitting the label.

    Note: Labels tested should be from commercial production operations. If preliminary testing is conducted on developmental labels from pilot-scale equipment, the testing should be repeated with commercially produced labels.

 Evaluation of PET Container Component

Color
The protocol does not purport to address all of the safety issues, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

  • Produce 100gram clear PET flake samples according to this procedure. Be sure to produce a sample of control flake from recycled PET bottles without the “bleeding label” to be evaluated.
  • Perform color analysis, according to the machine manufacturers instructions, on each sample produced (test of “bleeding label”-colored PET and control PET) using the following format:
    • Take five measurements, in reflectance or transmission, on each sample. Record data as X, Y, Z tristimulus values, CIE XYZ, CIE L*a*b*or Hunter L a b color coordinates, or equivalent. Adjust the position of the sample holder prior to each measurement to expose different sample areas to measurement.
    • Report all of the axis readings (such as L, a, b) for all five samples and the average for each sample.
  • Evaluation guidance. All three color measurements, L, a, and b, are important to the possible use of the recyclate. The human eye can discern about one b unit change. The L measures brightness vs dinginess of the flake. a measures red/green color components. b measures yellow/blue color components.

    Depending on the end use, different amounts of variation from the control can be accepted. Generally, changes of more than two a or b units or five L units are excessive. Absolute b values over 3 for flakes measured in reflection may be unacceptable for reuse in bottles.

    Comparisons should be made between control and test samples for the same treatment.
  • Discolored water should be evaluated to see if the discoloration is acceptable for release to municipal sewer systems without further treatment. Strongly discolored water is likely to be unacceptable to many municipal wastewater treatment systems and labels which cause such discoloration should be avoided.

The guidance contained in this document does not guarantee acceptance or rejection of tested materials. APR encourages users of this protocol to discuss results with various knowledgeable parties using and specifying post consumer PET material to determine usefulness of subject test materials. Any guarantees or warranties are expressly disclaimed, including without limitation any implied warranties of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.

 

 
 

1300 Wilson Boulevard Arlington, VA 22209 · 703- 741-5578 · 703-741-5646 (fax)
robin_cotchan@plastics.org · http://www.3cstudios.com